Hydril Pulsation Dampener Manual
SFU Series
- SFU o-ring
- SFU wing nut
- Dust cap
- Loading valve
- Bleeder valve
- Cartridge
- Case
SFV & SFVM Series
- 6″ or 8″ suction gasket
- 6″ or 8″ grooved coupling
- Dust cap
- Loading valve
- Bleeder valve
- Cartridge
- Case
SFT Series
Hydril Gl Annular Operating Manual Hydril - gk bop.pdf 1.2.4 Principle of Operation The Hydril GK 11'-5000 PSI annular BOP (Figure 1-2) is an 5-13 Operator's Manual GK 11'-5000 PSI. Motor for Slush Pump 2 pcs Electrical G.E.-752 15 Pulsation Dampener 2 pcs Hydril K pulsation dampener: hydril k20 Use manual type screeds Hydril pulsation dampener parts list - free pdf hydril pulsation dampener parts list at greenbookee.org Also lubricants, pulsation dampener and Koomey accumulator parts.Hydril Pul Ford 6000cd rds manual. The Hydril K-P Series Pulsation Dampener/Surge Stabilizer should be mounted in the vertical position (refer to Figure 1- 3 and 1-4 for mounting options) with the mating flange con- nection at the bottom. The discharge dampener should be mounted as close as possible to the discharge port of the pump. Hydril Type K ' Pulsation Dampener Replacement Diaphragms and Stabilizer for K-10 and K-20 Pulsation Dampeners. HYDRIL K20 Pulsation Bladders / Dampener and Bladder Kits Get Price/Quote Ask a Question Send Enquiry IPDTM – PPD (Production Pulsation Dampener Diaphragms IKDTM – DPD (Drilling Pulsa tion Dampner Diaphragms) We manufacture and export complete equivalent parts for Hydril dampener (which includes Hydril K20 Pulsation Bladders, Stabiliser Diaphragm, Stabiliser Plate, Lock Washer.
- HPG-1 gasket (Nitrile or EPDM)
- Dust cap
- Loading valve
- Bleeder valve
- Cartridge
- Case
SFM Series
- SFM o-rings (2 required)
- SFM wingnut
- Dust cap
- Loading valve
- Bleeder valve
- Cartridge
- Case
- SFM wingnut screw
CHARGE TO 80%- 90% OF SUCTION PRESSURE OR THE MAXIMUM CHARGE PRESSURE OF THE CARTRIDGE, WHICHEVER IS LESS. THIS IS ONLY AN APPROXIMATION.
(YOU MAY FIND IT NECESSARY TO DECREASE THE PRESSURE IN THE SUCTION CARTRIDGE TO ACHIEVE OPTIMUM PUMP PERFORMANCE.)
- Shut down pump and relieve line pressure from discharge side before closing suction valve. After discharge line is relieved of pressure, close suction line valve and drain suction line.
- Open bleeder valve ’A’.
- Remove loading valve protector cap ’B’.
- Remove cap from loading valve ’C’.
- Loosen safety nut ’D’ three full turns.
- Using NITROGEN ONLY, charge the cartridge through loading valve ’C’ to the recommended operating pressure (90% of suction pressure). (DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE).
- Tighten safety nut ’D’ on loading valve ’C’.
- Replace loading valve protector cap ’B’
- Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.
- Shut down pump and relieve line pressure.
- Open bleeder valve ’A’.
- Remove loading valve protector cap ’B’.
- Remove cap from loading valve ’C’.
- Loosen safety nut ’D’ three full turns.
- Using NITROGEN ONLY charge the cartridge through loading valve ’C’ to correct charge pressure (use chart below).
NOTE: DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE (ON CASE LABEL). - Tighten safety nut ’D’ on loading valve ’C’ and replace cap.
- Replace loading valve protector cap ’B’.
- Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.
Hydril K20-7500 Pulsation Dampener Manual
WARNING
THE USE OF ANY GAS OTHER THAN NITROGEN IS EXTREMELY DANGEROUS.
NEVER ATTEMPT TO CHARGE OR PRE-CHARGE A CARTRIDGE OUTSIDE OF THE PULSATION STABILIZER CASE.
Hydril K20 Pulsation Dampener Manual
Rapidweaver free for mac software. FOR PROPER CHARGING PROCEDURES REFER TO THE SUCTION OR DISCHARGE CHARGING GUIDE.